Home » Shop » hot sale » Absolute Process Instruments API 6380 G _ AC to DC transmitter. Fully isolated.

Absolute Process Instruments API 6380 G _ AC to DC transmitter. Fully isolated.

Original price was: $368.00.Current price is: $244.11.

Sale!

70 in stock

SKU: API 6380 G Category:

Absolute Process Instruments API 6380 G _ AC to DC transmitter. Fully isolated.

Features:

  • One Minute Setup for Hundreds of I/O Ranges
  • External Switches & Tables for Range Selection
  • Non-Interactive Zero and Span Calibration
  • Full 2000 V Input/Output/Power Isolation
  • Input and Output LoopTracker® LEDs
  • Output Test Button
  • Built-In Loop Power Supply for mA Output

Applications:

  • Convert AC Signals to DC Process Signals
  • Monitor Line Voltage or Current Levels
  • Isolate and Convert AC Signals for Panel Meters, PLCs, Recorders, Data Acquisition, DCS, & SCADA Systems

The API 6380 G accepts an AC voltage or current input and provides an optically isolated DC voltage or current output that is linearly related to the input. Accuracy is maintained over a wide frequency range for maximum flexibility. The input is a true RMS measurement for distorted AC inputs.

The full 3-way (input, output, power) isolation makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

20 input and 16 output ranges can be field-configured via external rotary and slide switches. Popular ranges are listed on the module label. Consult the factory for assistance with special ranges.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span. The output test button greatly aids in saving time during initial startup and/or troubleshooting.

Specifications Table:

AC Input Range Field selectable ranges via switch settings. System voltages must not exceed socket voltage rating.

  • Voltage: 0-50 mVAC to 0-250 VAC
  • Current: 0-5 mAAC to 0-200 mAAC

True RMS input measurement.

Input Impedance (Voltage Input)
  • Voltage (0-4 VAC): 1 MΩ minimum
  • Voltage (>4 VAC): 220 kΩ minimum
  • Current: 10 Ω typical
Input Frequency 40 Hz to 1000 Hz sinusoidal
Input Protection, Common Mode 750 VDC or 750 VACp
DC Output Range Factory configured, please specify output range.

  • Voltage: 0-1 VDC to 0-10 VDC
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-2 mADC to 0-20 mADC, 20 V compliance, 1000 Ω at 20 mA
Output Calibration Multi-turn zero and span potentiometers (±15% of adjustment range typical)
Output Loop Power Supply 20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMS
Output Test Potentiometer adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.1% of span
Response Time 200 milliseconds typical (0-90%)
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability, calculated, not tested
Isolation
  • 2000 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Installation Environment
  • IP 40, requires installation in panel or enclosure
  • Use API 008 or API 008 FS socket
  • Socket mounts to 35 mm DIN rail or can be surface mounted UL 508C pollution degree 2 environments or better
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max.