Absolute Process Instruments T16L12 _ transmitter. Fully isolated.
Cecomp Electronics, T16L12, ThermoPro® Loop Powered Temperature Transmitter, 12″ Fixed Probe Length
Features:
- 100 Ω Platinum RTD
- 316 Stainless Steel Probe
- 2 wire 4-20 mA Output with Programmable Range
- -58.0°F to 392.0°F or -50.0°C to 200.0°C
- NEMA 4X Housing
- User-programmable 4-20 mA output range
- Selectable °F or °C
- Pass code protected setup and calibration
Specifications Table:
| Range |
58.0 to 392.0°F or 50.0 to 200.0°C, selectable |
| Resolution |
0.1°F or 0.1°C resolution |
| Accuracy |
Includes linearity error and ±1 LSD 11-point linearization
- ±0.7°C at 50°C
- ±0.4°C at 0°C
- ±0.9°C at 100°C
- ±1.4°C at 200°C
|
| Display |
- 4 readings per second nominal display update rate
- 4 digit LCD, 0.5″ H
- 5 character 0.25″ H alphanumeric
- Low battery voltage indication(ALARM1 under range indication on display, ALARM2 over range indication on display)
|
| Sensor |
- IEC-751 Class B 100 Ω Platinum RTD, 0.00385 alpha curve 1 /2″ NPT male, 316L stainless steel
- All wetted parts are 316L stainless steel
- Probe pressure rating: 5000 psi max.
- Probes are welded to hex fitting
|
| Analog Output |
- 12,000 count 4-20 mA output
- Updated approximately 4 times per second
- Temperature range configurable to correspond to 4-20 mA output
- Configurable for upscale or downscale burnout
|
| Controls and Functions |
- 3 button front keypad for setup, calibration, and configuration.
- User-defined pass codes to prevent unauthorized changes.
- Pass code required for configuration and calibration.
|
| Output Test Function |
When TEST button is held loop current and display are set to test level, independent of temperature input, to allow testing of system operation. Test level is user set. Output test function can be pass code protected |
| Calibration |
- User settable pass code required to enter calibration mode
- Zero and span temperature calibration
- Non-interactive zero, span, and linearity, ±10% of range
|
| Weight |
- Product: 12 ounces (approximately)
- Shipping: 1 pound (approximately)
|
| Housing Materials |
ABS/polycarbonate NEMA 4X case, rear gasket, polycarbonate label, aluminum sensor block |
| Storage Temperature |
40 to 203°F (40 to 95°C) |
| Operating Range |
4 to 185°F (20 to 85°C) at housing |
| Cable Length |
12″ |
| Power |
- Any DC supply/loop resistance that maintains 8 to 32 VDC at gauge terminals
- Reverse polarity protected
- 3 ft long, 2-conductor 22 AWG cable
|